<?xml version="1.0"?><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xmlns:wgs84_pos="http://www.w3.org/2003/01/geo/wgs84_pos" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:rdaGr2="http://rdvocab.info/ElementsGr2" xmlns:oai="http://www.openarchives.org/OAI/2.0/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:dcterms="http://purl.org/dc/terms/"><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-CS6QBW1W/48cf79a8-ffc5-434c-b224-aa021931c3e0/PDF"><dcterms:extent>883 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-CS6QBW1W/cfa429ac-a2b1-4f26-88d3-fabdba7961d9/TEXT"><dcterms:extent>29 KB</dcterms:extent></edm:WebResource><edm:TimeSpan rdf:about="1992-2025"><edm:begin xml:lang="en">1992</edm:begin><edm:end xml:lang="en">2025</edm:end></edm:TimeSpan><edm:ProvidedCHO rdf:about="URN:NBN:SI:doc-CS6QBW1W"><dcterms:isPartOf rdf:resource="https://www.dlib.si/details/URN:NBN:SI:spr-FNIFVE9S" /><dcterms:issued>2022</dcterms:issued><dc:creator>Jarabek, Leon</dc:creator><dc:creator>Jensterle, Luka</dc:creator><dc:creator>Ležaič, Luka</dc:creator><dc:creator>Rep, Sebastijan</dc:creator><dc:creator>Tomše, Petra</dc:creator><dc:creator>Zaletel, Katja</dc:creator><dc:format xml:lang="sl">številka:2</dc:format><dc:format xml:lang="sl">letnik:56</dc:format><dc:format xml:lang="sl">str. 142-149</dc:format><dc:identifier>DOI:10.2478/raon-2022-0015</dc:identifier><dc:identifier>COBISSID_HOST:102526211</dc:identifier><dc:identifier>ISSN:1581-3207</dc:identifier><dc:identifier>URN:URN:NBN:SI:doc-CS6QBW1W</dc:identifier><dc:language>en</dc:language><dc:publisher xml:lang="sl">Association of Radiology and Oncology</dc:publisher><dcterms:isPartOf xml:lang="sl">Radiology and oncology (Ljubljana)</dcterms:isPartOf><dc:subject xml:lang="en">contrast recovery coefficient</dc:subject><dc:subject xml:lang="en">contrast-to-noise ratio</dc:subject><dc:subject xml:lang="sl">koeficient obnovitve kontrasta</dc:subject><dc:subject xml:lang="en">PET/CT</dc:subject><dc:subject xml:lang="sl">razmerje kontrast in šum</dc:subject><dc:subject xml:lang="sl">velikost voksela</dc:subject><dc:subject xml:lang="en">voxel size</dc:subject><dcterms:temporal rdf:resource="1992-2025" /><dc:title xml:lang="sl">Image reconstruction using small-voxel size improves small lesion detection for positron emission tomography|</dc:title><dc:description xml:lang="sl">Background. PET/CT imaging is widely used in oncology and provides both metabolic and anatomic information. Because of the relatively poor spatial resolution of PET, the detection of small lesions is limited. The low spatial resolution introduces the partial-volume effect (PVE) which negatively affects images both qualitatively and quantitatively. The aim of the study was to investigate the effect of small-voxel (2 mm in-line pixel size) vs. standard-voxel (4 mm in-line pixel size) reconstruction on lesion detection and image quality in a range of activity ratios. Materials and methods. The National Electrical Manufacturers Association (NEMA) body phantom and the Micro Hollow-Sphere phantom spheres were filled with a solution of 18Ffluorodeoxyglucose (18FFDG) in sphere-to-background ratios of 2:1, 3:1, 4:1 and 8:1. In all images reconstructed with 2 mm and 4 mm in-line pixel size the visual lesion delineation, contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR) were evaluated. Results. For smaller (? 13 mm) phantom spheres, significantly higher CRC and CNR using small-voxel reconstructions were found, also improving visual lesion delineation. CRC did not differ significantly for larger (? 17 mm) spheres using 2 mm and 4 mm in-line pixel size, but CNR was significantly lower; however, lower CNR did not affect visual lesion delineation. Conclusions. Small-voxel reconstruction consistently improves precise small lesion delineation, lesion contrast and image quality</dc:description><edm:type>TEXT</edm:type><dc:type xml:lang="sl">znanstveno časopisje</dc:type><dc:type xml:lang="en">journals</dc:type><dc:type rdf:resource="http://www.wikidata.org/entity/Q361785" /></edm:ProvidedCHO><ore:Aggregation rdf:about="http://www.dlib.si/?URN=URN:NBN:SI:doc-CS6QBW1W"><edm:aggregatedCHO rdf:resource="URN:NBN:SI:doc-CS6QBW1W" /><edm:isShownBy rdf:resource="http://www.dlib.si/stream/URN:NBN:SI:doc-CS6QBW1W/48cf79a8-ffc5-434c-b224-aa021931c3e0/PDF" /><edm:rights rdf:resource="http://creativecommons.org/licenses/by/4.0/" /><edm:provider>Slovenian National E-content Aggregator</edm:provider><edm:intermediateProvider xml:lang="en">National and University Library of Slovenia</edm:intermediateProvider><edm:dataProvider xml:lang="sl">Društvo radiologije in onkologije</edm:dataProvider><edm:object rdf:resource="http://www.dlib.si/streamdb/URN:NBN:SI:doc-CS6QBW1W/maxi/edm" /><edm:isShownAt rdf:resource="http://www.dlib.si/details/URN:NBN:SI:doc-CS6QBW1W" /></ore:Aggregation></rdf:RDF>