<?xml version="1.0"?><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xmlns:wgs84_pos="http://www.w3.org/2003/01/geo/wgs84_pos" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:rdaGr2="http://rdvocab.info/ElementsGr2" xmlns:oai="http://www.openarchives.org/OAI/2.0/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:dcterms="http://purl.org/dc/terms/"><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-H69MKDSN/eb16f094-3657-4f91-9b86-630dfbf9535c/PDF"><dcterms:extent>606 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-H69MKDSN/e91c31ce-61b5-487a-a8e5-0cd813732c39/TEXT"><dcterms:extent>31 KB</dcterms:extent></edm:WebResource><edm:TimeSpan rdf:about="1992-2025"><edm:begin xml:lang="en">1992</edm:begin><edm:end xml:lang="en">2025</edm:end></edm:TimeSpan><edm:ProvidedCHO rdf:about="URN:NBN:SI:doc-H69MKDSN"><dcterms:isPartOf rdf:resource="https://www.dlib.si/details/URN:NBN:SI:spr-FNIFVE9S" /><dcterms:issued>2024</dcterms:issued><dc:creator>Boltežar, Lučka</dc:creator><dc:creator>Kuhelj, Dimitrij</dc:creator><dc:contributor>Kuhelj, Dimitrij</dc:contributor><dc:creator>Pintarić, Karlo</dc:creator><dc:creator>Umek, Nejc</dc:creator><dc:format xml:lang="sl">številka:2</dc:format><dc:format xml:lang="sl">letnik:58</dc:format><dc:format xml:lang="sl">str. 206-213 , V</dc:format><dc:identifier>DOI:10.2478/raon-2024-0021</dc:identifier><dc:identifier>ISSN:1318-2099</dc:identifier><dc:identifier>COBISSID:195722755</dc:identifier><dc:identifier>URN:URN:NBN:SI:doc-H69MKDSN</dc:identifier><dc:language>en</dc:language><dc:publisher xml:lang="sl">Croatian Medical Association - Croatian Society of Radiology</dc:publisher><dc:publisher xml:lang="sl">Slovenian Medical Society - Section of Radiology</dc:publisher><dcterms:isPartOf xml:lang="sl">Radiology and oncology (Ljubljana)</dcterms:isPartOf><dc:subject xml:lang="sl">anevrizma aorte</dc:subject><dc:subject xml:lang="sl">dolgoročno spremljanje</dc:subject><dc:subject xml:lang="sl">prostorninske meritve</dc:subject><dc:subject xml:lang="sl">večplastni modulator pretoka</dc:subject><dcterms:temporal rdf:resource="1992-2025" /><dc:title xml:lang="sl">Long-term outcome of multilayer flow modulator in aortic aneurysms|</dc:title><dc:description xml:lang="sl">ckground. This retrospective study investigated the efficacy of endovascular treatment with multilayer flow modu-lators (MFMs) for treating aortic aneurysms in high-risk patients unsuitable for conventional treatments.Patients and methods. Conducted from 2011 to 2019 at a single center, this retrospective observational study in-cluded 17 patients who underwent endovascular treatment with MFMs. These patients were selected based on theirunsuitability for traditional surgical or endovascular procedures. The study involved meticulous pre-procedural plan-ning, precise implantation of MFMs, and follow-up using CT angiography. The primary focus was on volumetric andflow volume changes in aneurysms, along with traditional diameter measurements. Moreover, the technical successand post-procedural complications were also registered.Results. The technical success rate was 100%, and 30-day procedural complication rate was 17.6%. Post-treatmentassessments revealed that 11 out of 17 patients showed a decrease in flow volume within the aneurysm sac, indicativeof a favorable hemodynamic response. The median decrease in flow volume was 12 ml, with a median relative de-crease of 8%. However, there was no consistent reduction in aneurysm size; most aneurysms demonstrated a medianincrease in volume for 46 ml and median increase in diameter for 18 mm.Conclusions. While MFMs offer a potential alternative for high-risk aortic aneurysm patients, their effectiveness in pre-venting aneurysm expansion is limited. The results suggest that MFMs can provide a stable hemodynamic environmentbut do not reliably reduce aneurysm size. This underscores the need for ongoing vigilance and long-term monitoringin patients treated with this technology</dc:description><edm:type>TEXT</edm:type><dc:type xml:lang="sl">znanstveno časopisje</dc:type><dc:type xml:lang="en">journals</dc:type><dc:type rdf:resource="http://www.wikidata.org/entity/Q361785" /></edm:ProvidedCHO><ore:Aggregation rdf:about="http://www.dlib.si/?URN=URN:NBN:SI:doc-H69MKDSN"><edm:aggregatedCHO rdf:resource="URN:NBN:SI:doc-H69MKDSN" /><edm:isShownBy rdf:resource="http://www.dlib.si/stream/URN:NBN:SI:doc-H69MKDSN/eb16f094-3657-4f91-9b86-630dfbf9535c/PDF" /><edm:rights rdf:resource="http://creativecommons.org/licenses/by/4.0/" /><edm:provider>Slovenian National E-content Aggregator</edm:provider><edm:intermediateProvider xml:lang="en">National and University Library of Slovenia</edm:intermediateProvider><edm:dataProvider xml:lang="sl">Društvo radiologije in onkologije</edm:dataProvider><edm:object rdf:resource="http://www.dlib.si/streamdb/URN:NBN:SI:doc-H69MKDSN/maxi/edm" /><edm:isShownAt rdf:resource="http://www.dlib.si/details/URN:NBN:SI:doc-H69MKDSN" /></ore:Aggregation></rdf:RDF>