<?xml version="1.0"?><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xmlns:wgs84_pos="http://www.w3.org/2003/01/geo/wgs84_pos" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:rdaGr2="http://rdvocab.info/ElementsGr2" xmlns:oai="http://www.openarchives.org/OAI/2.0/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:dcterms="http://purl.org/dc/terms/"><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-PJVBDB0P/3982a999-1f83-4d8d-9c39-4b885593b598/HTML"><dcterms:extent>15 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-PJVBDB0P/1c859085-9f32-498c-883a-82be2eb40081/PDF"><dcterms:extent>184 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-PJVBDB0P/255f5d55-a613-47fa-bbec-9c5f6f9bf1fa/TEXT"><dcterms:extent>13 KB</dcterms:extent></edm:WebResource><edm:TimeSpan rdf:about="1992-2025"><edm:begin xml:lang="en">1992</edm:begin><edm:end xml:lang="en">2025</edm:end></edm:TimeSpan><edm:ProvidedCHO rdf:about="URN:NBN:SI:doc-PJVBDB0P"><dcterms:isPartOf rdf:resource="https://www.dlib.si/details/URN:NBN:SI:spr-FNIFVE9S" /><dcterms:issued>2003</dcterms:issued><dc:creator>Brnić, Zoran</dc:creator><dc:creator>Hebrang, Andrija</dc:creator><dc:creator>Obad Kovačević, Dragica</dc:creator><dc:format xml:lang="sl">številka:1</dc:format><dc:format xml:lang="sl">letnik:37</dc:format><dc:format xml:lang="sl">4 strani</dc:format><dc:format xml:lang="sl">str. 5-8</dc:format><dc:identifier>ISSN:1318-2099</dc:identifier><dc:identifier>COBISSID:16231385</dc:identifier><dc:identifier>URN:URN:NBN:SI:doc-PJVBDB0P</dc:identifier><dc:language>en</dc:language><dc:publisher xml:lang="sl">Association of Radiology and Oncology</dc:publisher><dcterms:isPartOf xml:lang="sl">Radiology and oncology (Ljubljana)</dcterms:isPartOf><dc:subject xml:lang="en">breast</dc:subject><dc:subject xml:lang="en">Breast Diseases</dc:subject><dc:subject xml:lang="en">diagnostika</dc:subject><dc:subject xml:lang="sl">Dojka, bolezni</dc:subject><dc:subject xml:lang="sl">dojke</dc:subject><dc:subject xml:lang="en">Film Dosimetry</dc:subject><dc:subject xml:lang="sl">Film, dozimetrija</dc:subject><dc:subject xml:lang="en">Mammography</dc:subject><dc:subject xml:lang="sl">Mamografija</dc:subject><dc:subject xml:lang="en">Radiation Dosage</dc:subject><dc:subject xml:lang="en">Radiation Monitoring</dc:subject><dc:subject xml:lang="sl">Sevanje, doziranje</dc:subject><dc:subject xml:lang="sl">Sevanje, monitorski nadzor</dc:subject><dc:subject xml:lang="sl">Termoluminiscentna dozimetrija</dc:subject><dc:subject xml:lang="en">Thermoluminescent Dosimetry</dc:subject><dcterms:temporal rdf:resource="1992-2025" /><dc:title xml:lang="sl">Mammographic oblique views 45° versus 60°| breast thickness, breast exposure and image quality|</dc:title><dc:description xml:lang="sl">Background. Standard screening mammography includes two views: craniocaudal and mediolateral oblique. In the mediolateral oblique projection a central beam angle can varies between 30° and 60°. Patients and methods. We compare the thickness of the compressed breast, time-current product, exposures and image quality in two different mammographic oblique views: 45° versus 60°. Ourstudy population consisted of 33 women in whom additional 60° films after standard 45° films were obtained for the objective diagnostic reasons. Results. The mean thickness of the compressed breast was significantly lower with an angle of 60° than with an angle of 45° (47.8 vs. 50.7 mm, p&lt;0.01); themean time current product and the mean breast exposure were significantly lower with an angle of 60° than with an angle of 45° (42.6 vs. 46.7 mAs, p&lt;0.01; 0.67 vs. 0.78 mGy, p&lt;0,01). The difference in the image quality has not reached statisticaI significance (but it exists!). Conclusions. By introducing 60° films instead of commonly used 45° films, mammograms of at least the same quality can be obtained with lower radiation dose, which is of great importance when we remind the great radiosensitivity of glandular breasttissue</dc:description><dc:description xml:lang="sl">Izhodišča. Pri standardnem presejalnem testu z mamografijo uporabljamo dvoje projekcij: kraniokavdalno in mediolateralno polstransko. Pri mediolateralni polstranski projekciji je kot centralnega žarka od 30° do 60°. Bolniki in metode. Primerjali smo debelino komprimirane dojke, zmnožek časa in električnega toka, izpostavljenost sevanju in kakovost slik pri dveh različnihmamografskih poševnih projekcijah: pod kotoma 45° in 60°. Preiskave smo naredili pri 33 ženskah, pri katerih smo zaradi diagnostičnih zahtev polegslikanja pod kotom 45° naredili tudi slikanje pod kotom 60°. Rezultati. Srednja vrednost debeline komprimirane dojke je bila pri slikanju pod kotom 60° statistično značilno nižja kot pod kotom 45° (47,8 vs. 50,7 mm, p&lt;0.01); pravtako sta bili tudi statistično značilno nižji srednji vrednosti zmnoška časa in eletričnega toka ter izpostavljenosti sevanju (42,6 vs. 46,7 mAs, p&lt;0.01; 0,67 vs. 0,78 mGy, p&lt;0.01). Našli smo tudi razliko v kakovosti slik, ki pa ni bila statistično značilno boljša. Zaključki. Z uporabo polstranske mamografske projekcije pod kotom 60°smo dosegli vsaj enako kakovost mamografskih slik ob nižji sevalni dozi, kar je zelo pomembno, saj je mlečna žleza v dojki zelo radiosenzitivna</dc:description><edm:type>TEXT</edm:type><dc:type xml:lang="sl">znanstveno časopisje</dc:type><dc:type xml:lang="en">journals</dc:type><dc:type rdf:resource="http://www.wikidata.org/entity/Q361785" /></edm:ProvidedCHO><ore:Aggregation rdf:about="http://www.dlib.si/?URN=URN:NBN:SI:doc-PJVBDB0P"><edm:aggregatedCHO rdf:resource="URN:NBN:SI:doc-PJVBDB0P" /><edm:isShownBy rdf:resource="http://www.dlib.si/stream/URN:NBN:SI:doc-PJVBDB0P/1c859085-9f32-498c-883a-82be2eb40081/PDF" /><edm:rights rdf:resource="http://creativecommons.org/licenses/by/4.0/" /><edm:provider>Slovenian National E-content Aggregator</edm:provider><edm:intermediateProvider xml:lang="en">National and University Library of Slovenia</edm:intermediateProvider><edm:dataProvider xml:lang="sl">Društvo radiologije in onkologije</edm:dataProvider><edm:object rdf:resource="http://www.dlib.si/streamdb/URN:NBN:SI:doc-PJVBDB0P/maxi/edm" /><edm:isShownAt rdf:resource="http://www.dlib.si/details/URN:NBN:SI:doc-PJVBDB0P" /></ore:Aggregation></rdf:RDF>