<?xml version="1.0"?><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xmlns:wgs84_pos="http://www.w3.org/2003/01/geo/wgs84_pos" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:rdaGr2="http://rdvocab.info/ElementsGr2" xmlns:oai="http://www.openarchives.org/OAI/2.0/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:dcterms="http://purl.org/dc/terms/"><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-PZ8WD43D/40b9dbc8-b73d-48ad-8ec6-5a793dc104e7/HTML"><dcterms:extent>45 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-PZ8WD43D/0d607141-88dc-4f79-ac8e-cf525ed62f02/PDF"><dcterms:extent>554 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-PZ8WD43D/a0cfd153-5d89-4ca8-bfbb-7e408bc41044/TEXT"><dcterms:extent>25 KB</dcterms:extent></edm:WebResource><edm:TimeSpan rdf:about="1992-2025"><edm:begin xml:lang="en">1992</edm:begin><edm:end xml:lang="en">2025</edm:end></edm:TimeSpan><edm:ProvidedCHO rdf:about="URN:NBN:SI:doc-PZ8WD43D"><dcterms:isPartOf rdf:resource="https://www.dlib.si/details/URN:NBN:SI:spr-FNIFVE9S" /><dcterms:issued>2008</dcterms:issued><dc:creator>Miklavčič, Damijan</dc:creator><dc:creator>Pavšelj, Nataša</dc:creator><dc:format xml:lang="sl">številka:3</dc:format><dc:format xml:lang="sl">letnik:42</dc:format><dc:format xml:lang="sl">str. 159-168</dc:format><dc:identifier>ISSN:1318-2099</dc:identifier><dc:identifier>COBISSID:6697300</dc:identifier><dc:identifier>URN:URN:NBN:SI:doc-PZ8WD43D</dc:identifier><dc:language>en</dc:language><dc:publisher xml:lang="sl">Association of Radiology and Oncology</dc:publisher><dcterms:isPartOf xml:lang="sl">Radiology and oncology (Ljubljana)</dcterms:isPartOf><dc:subject xml:lang="sl">biomedicina</dc:subject><dc:subject xml:lang="sl">elektrokemoterapija</dc:subject><dc:subject xml:lang="sl">elektroporacija</dc:subject><dc:subject xml:lang="sl">modeli</dc:subject><dc:subject xml:lang="sl">numerično modeliranje</dc:subject><dc:subject xml:lang="sl">tumorji</dc:subject><dcterms:temporal rdf:resource="1992-2025" /><dc:title xml:lang="sl">Numerical modeling in electroporation-based biomedical applications|</dc:title><dc:description xml:lang="sl">Background. Numerous experiments have to be performed before a biomedical application is put to practical use in clinical environment. As a complementary work to in vitro, in vivo and medical experiments, we can use analytical and numerical models to represent, as realistically as possible, real biological phenomena of, in our case, electroporation. In this way we canevaluate different electrical parameters in advance, such as pulse amplitude, duration, number of pulses, or different electrode geometries. Suchnumerical models can contribute significantly to the understanding of an experiment and treatment planning as well as to the design of new electroporation devices and electrodes. Methods. We used commercially available modeling software, based on finite element method. We constructed a model of a subcutaneous tumor during electrochemotherapy (EMAS) and a model ofskin during gene electrotransfer (COMSOL Multiphysics). Tissue-electrode geometries, pulse parameters and currentvoltage measurements from in vivo experiments were used to develop and validate the models. Results. To describeadequately our in vivo observations, a tissue conductivity increase during electroporation was included in our numerical models. The output currents of the models were compared to the currents and the voltages measuredduring in vivo experiments and a good agreement was obtained. Also, when comparing the voltages needed for a successful electropermeabilization assuggested by the models, to voltages applied in experiments and achieving a successful electrochemotherapy or in vivo gene electrotransfer, good agreementcan be observed. Conclusions. Modeling of electric current and electric field distribution during cell and tissue electroporation proves to be helpful in describing different aspects of the process and allowing us to design electrodes and electroporation protocols as a part of treatment planning</dc:description><edm:type>TEXT</edm:type><dc:type xml:lang="sl">znanstveno časopisje</dc:type><dc:type xml:lang="en">journals</dc:type><dc:type rdf:resource="http://www.wikidata.org/entity/Q361785" /></edm:ProvidedCHO><ore:Aggregation rdf:about="http://www.dlib.si/?URN=URN:NBN:SI:doc-PZ8WD43D"><edm:aggregatedCHO rdf:resource="URN:NBN:SI:doc-PZ8WD43D" /><edm:isShownBy rdf:resource="http://www.dlib.si/stream/URN:NBN:SI:doc-PZ8WD43D/0d607141-88dc-4f79-ac8e-cf525ed62f02/PDF" /><edm:rights rdf:resource="http://creativecommons.org/licenses/by/4.0/" /><edm:provider>Slovenian National E-content Aggregator</edm:provider><edm:intermediateProvider xml:lang="en">National and University Library of Slovenia</edm:intermediateProvider><edm:dataProvider xml:lang="sl">Društvo radiologije in onkologije</edm:dataProvider><edm:object rdf:resource="http://www.dlib.si/streamdb/URN:NBN:SI:doc-PZ8WD43D/maxi/edm" /><edm:isShownAt rdf:resource="http://www.dlib.si/details/URN:NBN:SI:doc-PZ8WD43D" /></ore:Aggregation></rdf:RDF>